Retinal Image Analysis: Image Processing and Feature Extraction Oriented to the Clinical Task

A.G. Marrugo, M. S. Millán


Download Paper

Base Information

Volume

V50 - N1 / 2017 Ordinario

Reference

49-62

DOI

http://doi.org/10.7149/OPA.50.1.49507

Language

English

Keywords

Computer-aided diagnosis, medical image, retinal image, telemedicine, ophthalmology

Abstract

Medical digital imaging has become a key element of modern health care procedures. It provides visual documentation and a permanent record for the patients, and most important the ability to extract quantitative information about many diseases. Modern ophthalmology relies on the advances in digital imaging and computing power. In this paper we present an overview of the results from the doctoral dissertation by Andrés G. Marrugo. This dissertation contributes to the digital analysis of retinal images and the problems that arise along the imaging pipeline of fundus photography, a field that is commonly referred to as retinal image analysis. We have dealt with and proposed solutions to problems that arise in retinal image acquisition and longitudinal monitoring of retinal disease evolution. Specifically, non-uniform illumination compensation, poor image quality, automated focusing, image segmentation, change detection, space-invariant (SI) and space-variant (SV) blind deconvolution (BD). Digital retinal image analysis can be effective and cost-efficient for disease management, computeraided diagnosis, screening and telemedicine and applicable to a variety of disorders such as glaucoma, macular degeneration, and retinopathy.

References

0

M. D. Abramoff, M. Garvin, and M. Sonka, "Retinal Imaging and Image Analysis," Biomedical Engineering, IEEE Reviews 3, 169–208, (2010). DOI

1

A. G. Marrugo, "Comprehensive Retinal Image Analysis: Image Processing and Feature Extraction Techniques Oriented to the Clinical Task.," Universitat Politècnica de Catalunya, Barcelona, (2013). http://hdl.handle.net/10803/134698

2

A. G. Marrugo, M. S. Millan, G. Cristóbal, S. Gabarda, and H. C. Abril, "No-reference Quality Metrics for Eye Fundus Imaging," CAIP 2011, LNCS, 6854, 486–493, (2011).

3

S. Gabarda and G. Cristóbal, "Blind image quality assessment through anisotropy," J Opt Soc Am A Opt Image Sci Vis, 24 , B42–51, (2007). DOI

4

Xiang Zhu and P. Milanfar, "Automatic Parameter Selection for Denoising Algorithms Using a No-Reference Measure of Image Content," IEEE Trans Image Process. 19, 3116–3132, (2010). DOI

5

R. Ferzli and L. J. Karam, "A no-reference objective image sharpness metric based on the notion of just noticeable blur (JNB)," IEEE Trans Image Process. 18, 717–728, (2009). DOI

6

Y. Qu, Z. Pu, H. Zhao, and Y. Zhao, "Comparison of different quality assessment functions in autoregulative illumination intensity algorithms," Opt. Eng. 45, 117201, (2006). DOI

7

A. G. Marrugo, M. S. Millan, G. Cristóbal, S. Gabarda, and H. C. Abril, "Anisotropy-based robust focus measure for non-mydriatic retinal imaging," J. Biomed. Opt., 17, 076021, (2012). DOI

8

M. Moscaritolo, H. Jampel, F. Knezevich, and R. Zeimer, "An Image Based Auto-Focusing Algorithm for Digital Fundus Photography," IEEE Trans. Med. Imaging, 28, 1703–1707, (2009). DOI

9

S. Nayar and Y. Nakagawa, "Shape from focus," IEEE Trans Pattern Anal Mach Intell, 16, 824–831, (1994). DOI

10

K. Choi, J. Lee, and S. Ko, "New autofocusing technique using the frequency selective weighted median filter for video cameras," IEEE T. Consum. Electr., 45, 820–827, (1999). DOI

11

M. Kristan, J. Pers, M. Perse, and S. Kovacic, "A Bayes-spectral-entropy-based measure of camera focus using a discrete cosine transform," Pattern Recognit. Lett., 27, 1431–1439, (2006). DOI

12

A. G. Marrugo, M. S. Millan, and H. C. Abril, "Implementation of an image based focusing algorithm for non-mydriatic retinal imaging," Engineering Mechatronics and Automation (CIIMA), 2014 III International Congress of, 1–3, (2014). DOI

13

A. G. Marrugo, Ed., Anisotropy focus measure. [Online Accessed: 17-Apr-2016]. Available at: Anisotropy focus

14

H. Narasimha-Iyer, A. Can, B. Roysam, C. Stewart, H. Tanenbaum, A. Majerovics, and H. Singh, "Robust detection and classification of longitudinal changes in color retinal fundus images for monitoring diabetic retinopathy," IEEE Trans. Biomed. Eng., 53, 1084–1098, (2005) DOI

15

A. G. Marrugo, F. Sroubek, M. Sorel, and M. S. Millan, "Multichannel blind deconvolution in eye fundus imaging," presented at the ISABEL '11-Proceedings of the 4th International Symposium on Applied Sciences in Biomedical and Communication Technologies, 7:1–5 (2011). DOI

16

N. Everdell, I. Styles, A. Calcagni, J. Gibson, J. Hebden, and E. Claridge, "Multispectral imaging of the ocular fundus using light emitting diode illumination," Rev. Sci. Instrum., 81, 093706–093709, (2010). DOI

17

A. G. Marrugo, M. Sorel, F. Sroubek, and M. S. Millan, "Retinal image restoration by means of blind deconvolution," J. Biomed. Opt., 16, 11, 116016, (2011). DOI

18

C. Stewart, Chia-Ling Tsai, and B. Roysam, "The dual-bootstrap iterative closest point algorithm with application to retinal image registration," IEEE Trans. Med. Imaging, 22, 1379–1394, (2003).

19

T. Aach and A. Kaup, "Bayesian Algorithms for Change Detection in Image Sequences Using Markov Random Fields," Signal Process. Image 7, 147–160, (1995) DOI

20

A. Levin, Y. Weiss, F. Durand, and W. Freeman, "Understanding Blind Deconvolution Algorithms," IEEE Trans Pattern Anal. Mach Intell., 12, 2354–2367, (2011). DOI

21

A. G. Marrugo, M. S. Millan, G. Cristóbal, S. Gabarda, M. Sorel, and F. Sroubek, "Image analysis in modern ophthalmology: from acquisition to computer assisted diagnosis and telemedicine," presented at the Proceedings SPIE, 8436, 84360C–84360C–10 (2012). DOI

22

C. Muramatsu, Y. Hayashi, A. Sawada, Y. Hatanaka, T. Hara, T. Yamamoto, and H. Fujita, "Detection of retinal nerve fiber layer defects on retinal fundus images for early diagnosis of glaucoma," J. Biomed. Opt., 15, 016021, (2010). DOI

23

L. Xu and S. Luo, "Optimal algorithm for automatic detection of microaneurysms based on receiver operating characteristic curve," J. Biomed. Opt., 15, 065004, (2010). DOI

24

P. Bedggood, M. Daaboul, R. Ashman, G. Smith, and A. Metha, "Characteristics of the human isoplanatic patch and implications for adaptive optics retinal imaging," J. Biomed. Opt., 13, 024008, (2008). DOI

25

A. G. Marrugo, M. S. Millan, M. Sorel, and F. Sroubek, "Restoration of retinal images with space-variant blur," J. Biomed. Opt., 19, no. 1, p. 016023, Jan. 2014. DOI

26

A. G. Marrugo, M. S. Millan, M. Sorel, J. Kotera, and F. Sroubek, "Improving the blind restoration of retinal images by means of point-spread-function estimation assessment," presented at the Tenth International Symposium on Medical Information Processing and Analysis, 9287, 92871D (2015).

27

M. Tallón, J. Mateos, S. D. Babacan, R. Molina, and A. K. Katsaggelos, "Space-variant blur deconvolution and denoising in the dual exposure problem," INFORMATION FUSION, (2012).

28

A. G. Marrugo, M. S. Millan, M. Sorel, and F. Sroubek, "Blind restoration of retinal images degraded by space-variant blur with adaptive blur estimation," presented at the 8th Ibero American Optics Meeting/11th Latin American Meeting on Optics, Lasers, and Applications 8785, 8785D1 (2013)