Influence of the incisions of cataract surgery on corneal aberrations

J. Queiruga, A. Gargallo, J. Arines, F. González


Download Paper

Base Information

Volume

V48 - N1 / 2015 Ordinario

Reference

19-30

DOI

http://dx.doi.org/10.7149/OPA.48.1.19

Language

Spanish / Español

Keywords

Aberrations, Cataract surgery, 1 incision, Paired incisions, Sirius, Corneal topography.

Abstract

The aim of this work is to study the effects produced by 1 incision and paired incisions in corneal aberrations after cataract surgery. We selected 21 eyes of 18 patients aged between 44 and 89 years (69,81 ± 12.55). Aberrations were measured by corneal topographer Sirius 5 eyes with incisions paired (3 mm) and 16 eyes 1 corneal incision (2.2 mm). Data of topography, RMS values, and Zernike coefficients to 4th order were obtained a week before and 3-4 weeks after surgery for a pupil diameter of 6 mm. Corneal astigmatism was reduced with paired incisions (pre 0.94 ± 0.44 D, post 0.90 ± 0.48 D) (P =0.26) and increased with an incision (pre 1.29 ± 1.28 D, post 1.34 ± 1.45 D) (P = 0.77) Although differences were no statistically significant. The total RMS average increased with paired incisions (pre 1.16 ± 0.39 µm, post 1.24 ± 0.34 µm) (P = 0.46) and decreased with an incision (pre 1.76 ± 1.47 µm and post 1.54 ± 1.58 µm) (P = 0.91) after surgery. Higher order aberrations increased with paired incisions and decreased with 1 incision. The comma (pre 0.40 ± 0.19 µm, post 0.40 ± 0.30 µm) with paired incisions and spherical aberration (pre 0.31 ± 0.24 µm, post 0.31 ± 0.18 µm) with 1 incision showed no change post-surgical. These two types of incisions, although they induce changes after cataract surgery in aberrations corneal as clover, coma, astigmatism, tetrafoil, secondary astigmatism and spherical aberration, not impaired significantly the optical quality of the corneal surface.

References

0

World Health Organization. WHO: Geneva, Fact Sheet nº142-144.

1

P. J. Buckhurst, J. S. Wolffsohn, L. N. Davies, S. A. Naroo, "Surgical correction of astigmatism during cataract surgery", Clin. Exp. Optom. 93, 409-418 (2010). DOI

2

K. Kanawo, "Modified corneoscleral incision to reduce postoperative astigmatism after 6 mm diameter intraocular lens implantation", J. Catarac.t Refract. Surg. 19, 387-392 (1994). DOI

3

S. Marcos, "Calidad óptica del ojo", Investigación y ciencia. 345, 66-74 (2005)

4

A. Tytiun, M. J. Botta, P. Chiaradía, G. Martin, "Aberrometría Corneal Pre y Post Cross Linking Seguimiento a 18 meses", Arch. Oftal. B. Aires. 80, 65-66 (2009).

5

J. Tabernero, P. Piers, P. Artal, "Intraocular lens to correct corneal coma", Opt. Lett. 32, 406-408 (2007). DOI

6

N. Tong, J. C. He, F. Lu, Q. Wang, J. Qu, Y. E. Zhao, "Changes in corneal wavefront aberrations in microincision and small-incision cataract surgery",J. Cataract. Refract. Surg. 34, 2085-2090 (2008). DOI

7

K. Yao, X. Tang, P Ye, "Corneal astigmatism, high order aberrations, and optical quality after cataract surgery: microincision versus small incision",J. Refract. Surg. 22, S1079-82 (2006).

8

J. L. Alió, B. Elkady, D. Ortiz, "Corneal Optical Quality Following Sub 1.8 mm Micro-Incision Cataract Surgery vs. 2.2 mm Mini-Incision Coaxial Phacoemulsification", Middle East Afr. J. Ophthalmol. 17, 94-99 (2010).

9

J. Wang, E. K. Zhang, W. Y. Fan, J. X. Ma, P. F. Zhao, "The effect of micro-incision and small-incision coaxial phacoemulsification on corneal astigmatism", Clin. Experiment. Ophthalmol. 37, 664-669 (2009). DOI

10

A. Guirao, P. Artal, "Corneal wave aberrations from videokeratography: accuracy and limitations of the procedure", J. Opt. Soc. Am. A 17, 955-965 (2000). DOI

11

A. Guirao, M. Redondo, E. Geraghty, P. Piers, S. Norrby, P. Artal, "Corneal optical aberrations and retinal image quality in patients in whom monofocal intraocular lenses were implanted," Arch. Ophthalmol. 120, 1143-1151 (2002). DOI

12

K. Hayashi, M. Yoshida, H. Hayashi, "Postoperative corneal shape changes: Microincision versus small-incision coaxial cataract surgery," J. Cataract. Surg. 35, 233-9 (2009). DOI

13

G. Savini, P. Barboni, M. Carbonelli, K. J. Hoffer, "Repeatability of automatic measurements by a new Scheimpflug camera combined with Placido topography", J. Cataract. Refract. Surg. 37, 1809-1816 (2011). DOI

14

A Guirao, J. Tejedor, P. Artal, "Corneal aberrations before and after small-incision cataract surgery", Invest. Ophthalmol. Vis. Sci. 45, 4312-4319 (2004). DOI

15

R. F. Steiner, S. F. Brint, S. M. White, I. H. Fine, "Astigmatism after small incision cataract surgery: a prospective, randomized, multicenter comparison of 4- and 6.5-mm incisions", Ophthalmology 98 417-423, (1991). DOI

16

Z. Z. Nagy, A. Dunai, K. Kránitz, A. I. Takács, G. L. Sándor, R. Hécz, M. C. Knorz, "Evaluation of femtosecond laser-assisted and manual clear corneal incisions and their effect on surgically induced astigmatism and higher-order aberrations", J. Refract. Surg. 30, 552-5 (2014). DOI?

17

H. Ramzjoo, N. Koosha, M. H. Vaezi, B. Rahimi, A. Peyman, "Corneal astigmatism change and wavefrontaberration evaluation after cataract surgery: "Single" versus "paired opposite" clear corneal incisions", Adv Biomed Res. 3, 163 (2014). DOI

18

S. Khokhar, P. Lohiya, V. Murugiesan, A. Panda, "Corneal astigmatism correction with opposite clear corneal incisions or single clear corneal incision: comparative analysis", J. Cataract. Refract. Surg. 32, 1432-1437 (2006). DOI

19

B. Elkady, J. L. Alió, D. Ortiz, R. Montalbán, "Corneal aberrations after microincision cataract surgery", J. Cataract. Refract. Surg. 34, 40-45 (2008). DOI

20

A. R. Gutierrez, "Asfericidad corneal". Simposium de patología corneal 31; 3-26. (2002).

21

S. Marcos, P. Rosales, L. Llorente, I. Jiménez-Alfaro, "Change in corneal aberrations after cataract surgery with 2 types of aspherical intraocular lenses", J. Cataract. Refract. Surg. 33 217-226 (2007). DOI

22

I. Romero "Incisión corneal 1,8 vs 2,2 :¿hasta dónde?", Facoelche (2011).

23

S. Marcos, D. Cano, S. Barbero, "Increase in corneal asphericity after standard laser in situ keratomileusis for myopia is not inherent to the Munnerlyn algorithm", J. Refract. Surg. 19, 592-596 (2003).