Microtopographic non-invasive inspection for determining roughness parameters of dental biomaterials

A.Fernández-Oliveras, M.F.Martins Costa, M.M.Pérez


Download Paper

Base Information

Volume

V47 - N2 / 2014 VII Workshop on Lidar Measurements in Latin America

Reference

131-138

DOI

http://dx.doi.org/10.7149/OPA.47.2.131

Language

Spanish / Español

Keywords

Roughness Parameters, Microtopography, Non-Invasive Inspection, Biomaterials, Dental-Resin Composites, Zirconia Ceramics.

Abstract

In this work we experimentally analyze the roughness parameters of two types of dental-resin composites and pre-sintered and sintered zirconia ceramics. We studied two shades of both composite types and two sintered zirconia ceramics: colored and uncolored. A surface treatment was applied to one specimen of each dental-resin. The samples were submitted to non-invasive inspection with the MICROTOP.06.MFC laser microtopographer to gather meaningful surface statistical parameters. For a comparison of the different biomaterials, the uncertainties associated to the surface parameters were also determined. Except for the composites with the surface treatment, the sample surfaces had approximately a normal distribution of heights.

References

0

M. Quirynen, M. Marechal, H. J. Busscher, A. H.Weerkamp, P. L. Darius, D. Van Steenberghe, "The influence of surface free energy and surface roughness on early plaque formation. An in vivo study in man", J. Clin. Periodontal. 17, 138-144 (1990). DOI

1

M. Quirynen, H. C. van der Mei, C. M. Bollen, A. Schotte, M. Marechal, G. I. Doornbusch, I. Naert, H. J. Busscher, D. Steenberghe, "An in vivo study of the influence of the surface roughness of implants on the microbiology of supra- and subgingival plaque", J. Dent. Res. 72, 1304-1309 (1993). DOI

2

C. Wu-Yuan, K. Eganhouse, J. Keller, K. Walters, "Oral bacterial attachment to titanium surfaces: a scanning electron microscopy study",J. OralImplantol. 21, 207-213 (1995).

3

C. Bollen, W. Papaioannou, J. Van Eldere, E. Scheppers, M. Quirynen, D. Van Steenberghe, "The influence of abutment surface roughness on plaque accumulation and peri-implant mucositis", Clin. Oral Implant. Res. 7, 201-211 (1996). DOI

4

M. Quirynen, C. Bollen, W. Papaioannou, J. Van Eldere, D. Van Steenberghe, "The influence of titanium abutments surface roughness on plaque accumulation and gingivitis. Short term observations", Int. J. Oral Maxillofac. Implants. 11, 169-178 (1996).

5

S. B. Mitra, D. Wu, B. N. Holmes, "An application of nanotechnology in advanced dental materials", J. Am. Dent. Assoc. 134, 1382-1390 (2003). DOI

6

J. Denrya, R. Kellyb, "State of the art of zirconia for dental applications", Dent. Mater. 24, 299-307 (2008). DOI

7

J. Chevalier, L. Gremillard, "Ceramics for medical applications: A picture for the next 20 years", J. Eur. Ceram. Soc. 29, 1245-1255 (2009). DOI

8

A. Fernandez-Oliveras, M. Rubino, M. M. Perez, "Scattering and absorption properties of biomaterials for dental restorative applications", J. Eur. Opt. Soc. Rap. Public. 8, 13056 (2013). DOI

9

A. Fernandez-Oliveras, M. Rubino, M. M. Perez, "Analisis comparativo de medidas de anisotropi'a de scattering en tejidos y biomateriales dentales", Opt. Pura Apl. 46, 183-188 (2013). DOI

10

A. Fernandez-Oliveras, M. Rubino, M. M. Perez, "Scattering anisotropy measurements in dental tissues and biomaterials",J. Eur. Opt. Soc. Rap. Public. 7, 12016 (2012). DOI

11

M. F. M. Costa, "Optical triangulation-based microtopographic inspection of surfaces", Sensors 12, 4399-4420 (2012). DOI

12

M. C. L. Pacheco, M. F. M. Costa, A. J. P. Zapata, J. D. Cherit, E. R. Gallegos, "Implementation and analysis of relief patterns of the surface of benign and malignant lesions of the skin by microtopography", Phys. Med. Biol. 50, 5535-5543 (2005). DOI

13

M. F. M. Costa, P. B. Pereira, "Optical microtopographic inspection of the surface of tooth subjected to stripping reduction", Proc. SPIE 8001, 80012X (2011). DOI

14

M. F. M. Costa, "Surface Inspection by an optical triangulation method", Opt. Eng. 35, 2743-2747 (1996). DOI

15

M. F. M. Costa, V. Teixeira, "Rugometric and Microtopographic Inspection of Cr-Cr2O3 cermet solar absorbers", Int. J. Photoenergy 1110-662X, 82327 (2007). DOI

16

M. F. M. Costa, C. Batista, A. Portinha, V. Teixeira, C. R. Oliveira, R., Ribeiro, "Microtopographic inspection of laser glazed thermal barrier coatings", Opt. Eng. 47, 063603 (2008). DOI

17

International Organization for Standardization, Guide to the Expression of Uncertainty in Measurement. Corrected and reprinted (Geneva, 1995)